SFE Series In-Tank

Series Tank
Mounted |
Description HYDAC Suction Strainer Elements are designed for
installation into suction lines of pumps. Extra caution should
be taken to ensure that the suction elements are always
mounted below the minimum oil level of the reservoir. The
suction strainer elements can be supplied with a bypass valve
to reduce high pressure drops caused by contaminated elements
or high viscosity fluids during cold starting. The bypass
valve opens at 3 psi. for best results, suction strainer
elements should be sized for clean element pressure drops of
no higher than 0.5 to 0.7 psi. HYDAC suction Strainer
Elements are manufactured using stainless steel wire screen
media, plastic nut cap, and steel end cap. Suction strainer
elements are only intended to protect hydraulic pumps against
catastrophic failure caused by coarse contaminant. Suction
strainer elements should be inspected and cleaned
regularly. Suction strainer elements should not be used as
the only filtration elements in a hydraulic system. Pressure
filters and return line filters, with reasonable dirt holding
capacity, must be installed to provide protection against
component damage caused by fine
contaminants.
Cleaning Procedure
Remove external build-up of contaminant with
cleaning fluid in separate tank. Flush element with
clean solvent and blow through wire screen media with
air. |
|
|